How to Set and Adjust Limits on a Somfy RTS Roller Blind Motor
Upper and lower limits tell a Somfy motor where the roller blind must stop. Incorrect limits can leave fabric loose, drive the bottom rail too high or make the motor stop before the window is covered.
Start with the complete Somfy Remote Controls Guide if you have not confirmed the motor protocol, remote family or programming state.
This commissioning sequence is commonly used for compatible electronic-limit Sonesse RTS motors. Confirm the exact motor instructions before changing an established installation.
Before setting limits
Work on one motor at a time.
Select the correct individual remote channel.
Keep the blind in view and be ready to stop it.
Make sure the fabric rolls squarely and nothing is obstructing the blind.
Do not treat initial commissioning as a general reset.

Check and correct motor direction
Press UP and DOWN together until the uncommissioned motor jogs.
Press UP briefly.
If the blind moves up, continue.
If it moves down, hold MY until the motor jogs, then test UP again.
Set the initial upper and lower limits
Move the blind to the required upper position and fine-tune it carefully.
Press MY and DOWN together, then release when the blind starts moving down.
Press MY at the required lower position and fine-tune the lower limit.
Press MY and UP together, then release when the blind starts moving up.
Press MY to stop the blind.
Hold MY until the motor jogs to confirm the limits.
Briefly press the rear PROG button to record the transmitter and finish commissioning.
A motor without confirmed limits may continue moving until you stop it. Keep the blind in sight throughout commissioning.
Adjusting an already-programmed motor
Do not automatically repeat the new-motor procedure on an established blind. Limit-adjustment sequences vary between Somfy motor families and generations. Identify the motor label and use the model-specific instructions.
If the blind still reaches both limits but one position is wrong, use the model’s limit-adjustment procedure.
If the blind has lost all response, troubleshoot power, battery, channel and protocol before changing limits.
If the blind stops early only under load, check charging, obstruction, fabric tracking and torque rather than assuming the limit moved.
If several blinds move together, select an individual channel before programming.
Common symptoms
Symptom | Likely area to check |
Blind moves opposite to UP/DOWN | Motor direction was not confirmed |
Blind stops too high or too low | Saved limit position |
Blind will not leave programming mode | Commissioning confirmation or PROG step |
Blind stops early under load | Battery, obstruction, tube or torque |
Several blinds jog together | Group channel or multiple motors powered |
If the remote itself is unreliable, use the Somfy remote troubleshooting guide first.
Frequently asked questions
Can I set limits with any RTS remote?
Use a compatible RTS transmitter with access to the required UP, MY/STOP, DOWN and PROG controls.
Why does the motor jog?
A jog is the motor’s short confirmation movement that it has entered or accepted a programming step.
Will changing limits delete the remote?
A normal model-specific limit adjustment should not be treated as a factory reset, but incorrect programming can alter the setup. Follow the exact motor procedure.
Why does the blind stop before the lower limit?
Check battery charge, obstruction, fabric tracking and motor load. An early stop is not always a limit problem.
Should I reset the motor and start again?
Only after identifying the exact model and understanding the consequences. A reset may remove remotes, groups, favourite positions and limits.


